New Persyst EEG Suite Version 2007.10.08. This new version of the Persyst EEG Suite marks a significant step forward in the use of digital EEG for the monitoring and treatment of critically ill and EMU patients. Four new major features score a grand slam of improvements in the application of EEG monitoring.
ClearTrend: Adaptive Artifact Rejection. Detects artifact channels on-the-fly, and dynamically removes them from MagicMarker trend calculations. Channels are automatically returned when artifact abates.
ElectroDX: Alerts clinicians to artifact-ridden electrodes with a simple, easy to read display - regardless of the cause. This allows the cause of the artifact to be addressed directly to improve the accuracy of EEG monitoring.
EASI Single-Panel Trending: Are you overwhelmed with all the options for monitoring patients? EASI is the answer - a single panel which combines Asymmetry Trends (absolute and relative), SQRT scaling of spectogram data, ADR suppression ratio, and aEEG in a single trend panel for virtually any clinical application.
- MagicMarkerMail: It all comes together with the new integrated email client that sends notifications with images of trend and underlying EEG waveforms. ClearTrend makes this feature even more useful by reducing or eliminating the number of false notifications caused by artifact.
In addition to these new features, we continue to enhance the program to improve your experience with the Persyst EEG Suite. The following enhancements have also been made to our family of products:
Insight II - increased exporting options, improved user control of comments tab display and setup, addition of the balanced reference setup and improved auto-save features to prevent loss of data.
Reveal - the best in spike detection and review has gotten faster and more efficient in its CPU utilization.
MagicMarker - improved ability to set up and view notification thresholds, and automated channel setup.
- File Formats: We added support for the BioSignal format.
Download the new EEG Suite! HERE
If you are still using an older version of our software you are missing out on many new developments. This is a great time to upgrade your existing software and receive a full year of upgrades. With upgrades priced at only 35% of list price this is a deal that is too good to pass up! Check out our upgrade pricing page for more details. HERE
Finally, we are expanding our ability to provide the very best in training for you and your staff through our Persyst Training Online Workshops. Get the most out of the Persyst EEG tools by taking advantage of this free training which can be customized to your specific needs.

Persyst EEG Suite Version 2007.03.12a. This release includes these enhancements:
- We continue to support more file formats than any other EEG Analysis product on the market. This year we have added new or improved support for PolyMate Ambulatory/PSG recorders, Rembrandt MRS, and OSG-Brain RT format.
- Improved flexibility and functionality of the notification features in Insight II providing the ability to target your precise notification needs.
- Increased speed and performance for MagicMarker, Reveal and Insight II.
- Improved ability to customize preferences for MagicMarker.

Persyst EEG Suite Version 2006.10.10 includes: File format updates for Grass-Telefactor (video now supported) Natus-Biologic CEEGraph (feature enhancements), Xltek (feature enhancements), and others. MagicMarker’s handling of settings files has been simplified (automatic loading of previous scan parameters). Reveal spike and seizure detection: Automatic Sensitivity (uV/mm) is more robust, i.e., it will determine if there is sufficient background recorded to complete calculations. AutoLearn feature-complete for automatic notifications prompted from patient-dependent detectors. Find out more from the "What's New in This Version" link on the download page! HERE

New Persyst EEG Suite Version 2006.01.26 and new Multi-EEG Format Database version 2005.09.01!. AutoLearn Patient-Dependent Detection makes its debut, with sensitivity that closely approaches human performance! Create your own high-performance PNN (Probablistic Neural Network) detectors in less than a second just by marking the waveform of interest, and incremental learning is supported too. (Manuscript: A neural network method for automatic and incremental learning applied to patient dependent seizure detection, Journal of Clinical Neurophysiology, 116 (2005) pp. 1785-1795 (reprints available). AutoLearn is currently a beta release: Contact Persyst for a Trial Key if you would like a test-drive!): Plus, new Burst-Supression Ratio trends in MagicMarker, streamlined MagicMarker settings files, updated EEG file format support, and more.

New Persyst EEG Suite Version 2005.03.29. New Multi-EEG Format Database! Plus, faster scanning of multi-file recordings with Reveal, updated Reveal event notifications, updated EEG file format support, and more.

December 24, 2004
We know that you've been good all year, so we've been working hard for you (you are the focus of all we do!) to put some extra-special goodies into your EEG Suite Stocking (hung by the chimney with care...;-)

New Persyst EEG Suite Version 2004.11.22. New QuickStats tool in Insight II for one-touch measurement of voltage and frequency-- just drag a box around the waveform of interest to measure. Plus, a faster maximum paging speed, enhancements to channel subset selections (especially handy for grids) and new central-location storage of montages, custom filters and more (this lets you set up one review station, then "clone" the settings for the rest of them over your network). iMagicMarker brings dramatic speed improvements (7x faster processing and 10-20x faster review). There are even new tools for the Electrode Map Editor for even faster creation/editing of custom maps for your grid patients.

April 22, 2004
New Persyst EEG Suite Version 2004.03.25. New Reveal Generation III: The best gets even better, with enhanced spike and seizure detection accuracy. New features in Insight II with NeoPrism: The Next Generation of EEG review and analysis, and new/updated EEG file support.

March 12, 2004
New On-Line User Guide and Video Overviews Page . Full On-Line User's Guide for the Persyst EEG Suite with Insight II, NeoPrism, iReveal, iMagicMarker, and Report. See the new On-Line User Guide and Video Overviews page HERE

March 12, 2004
No Internet access from your acquisition or review stations? Download and install the Help System/On-Line User's Guide for EEG Suite version 2003.11.24 and later HERE Or contact Persyst for a CD-ROM upgrade HERE Has it been more than a year since you've purchased or upgraded? Check out the EEG Suite Upgrade Subscription page HERE

December 4, 2003
New Insight II Electrode Map Editor: In all versions 2003.11.24 and later, the new Electrode Map Editor brings many new ease-of-use features for creating custom maps for grids and/or strip electrode placements. See how it's done at the new On-Line User Guide and Video Overviews page HERE

December 1, 2003
New Persyst EEG Suite Version 2003.11.24. Insight II with NeoPrism: The Next Generation of EEG review and analysis, Now Released!

July 28, 2003
New Persyst EEG Suite Version 2003.07.16. Insight II with NeoPrism: The Next Generation of EEG review and analysis, now in 30-day preview mode! Also, there's new file format support/enhancements, and more in the latest update to the Persyst EEG Suite! EEG Suite version 2003.07.16.

April 14, 2003
New Persyst EEG Suite Version 2003.03.18. New Persyst Report, new file format support/enhancements, and more are in the latest update to the Persyst EEG Suite EEG Suite version 2003.03.18.

January 2, 2003
New Application Note: Compressed Spectral Array as an Adjunct for Interpreting Long Term EEG Monitoring. Many thanks to our friends at the Comprehensive Epilepsy Center, Dept. of Neurology, Neurological Institute, Columbia University College of Physicians and Surgeons, New York, NY, for providing the latest Application Note!

December 11, 2002
New Persyst EEG Suite Version 2002.11.19. Reveal spike detection now features Auto Sensitivity (uV/mm) for improved accuracy and ease of use when scanning any EEG with unusual amplitude-- high or low (any range of EEG activity, including intracranial).

October 9, 2002
New Reveal Interactive Demo. See how Reveal is the next generation of accuracy, simplicity, and flexibility.

October 8, 2002
Persyst Upgrade Subscription—Now On-Line The EEG Suite includes a full year of free software upgrades. Stay on the cutting edge with the Persyst Software Upgrade Subscription . This provides another full year of software upgrades with the latest file formats, new features, and enhancements. See the new Upgrade Subscription Page to find out more about how to stay on the cutting edge of EEG technology.

August 12, 2002
New Persyst EEG Suite Version 2002.08.12. Enhancements and fixes for improved integration and file support, as well as new digital video support for SnapShots "free review" export files.

March 22, 2002
New Persyst EEG Suite Version 2002.03.15. Fix for EDF/Lifelines format data, "server busy" messages, Reveal detection on recordings with a calibration signal, and more.

March 6, 2002
New Persyst EEG Suite Version 2002.02.28. New DigiTrace Digital Video support, enhanced support for Bio-logic multi-file formats, new Micromed file support, and more.

February 1, 2002
Reveal Spike and Seizure Detection has arrived! The new Persyst EEG Suite brings the best in automated spike and seizure detection with the introduction of Reveal.
New web-based software registration: Register your new software purchase, or upgrade your existing software registration/unlock with our new on-line registration form HERE.

January 25, 2002
Insights Fall/Winter 2001: The Balanced Non-Cephalic Reference and New Split-Montage View in Insight.

August 16, 2001
New Persyst EEG Suite: Integrated Persyst VideoPlayer, new file formats supported (and a handy way to sort them), and other enhancements throughout the EEG Suite. Find out more about these and other New Program Features and Enhancements in version 2001.07.12

April 12, 2001
Introduction to Hierarchical Clustering is a new clinical application note that discusses the basics of how SpikeReview is used to perform detailed analysis of spike events. Find out how to put the cluster plots and histograms to work for you.

January 29, 2001
New Persyst EEG Suite: Now you can view both numeric and trace data for your DC channels (e.g., SaO2, Heart Rate, etc.) in Insight and MagicMarker. Find out more about these and other New Program Features and Enhancements in version 2001.01.08
New Persyst VideoPlayer: View your digital video with Insight! Have you ever wished that you could view your digital video from Insight? Now you can! The new Persyst VideoPlayer provides a fully integrated, synchronized, and easy to use system for reviewing your synchronized EEG/DV (digital video) recordings — even while the recording is in progress. The VideoPlayer is only supported by EEG Suite version 2001.01.08 or later (see the installation instructions on the appropriate download page (trial or upgrade) for details).
Insights back issues: Check out back issues of the Insights newsletter, and sign up to receive new issues here!

October 11, 2000
Persyst Snapshots! Tired of EEG recordings that are tied to the lab? New Persyst SnapShots creates EEG recordings that can be read anywhere at no cost to the recipient. Use SnapShots with the Archive Tool's new EEG compression feature to create EEG segments small enough to e-mail. Find out more about these and other New Program Features and Enhancements in version 2001.01.08.

May 10, 2000
New Clinical Applications Notes on the FAQ page: Optimizing SpikeDetector Parameters for Long Term Monitoring and Extracting Information from Difficult Recordings.

August 4, 1999
On-Line User's Guide Update: If you are using version 1999.03.08 to 1999.06.23, download the new EEG Suite Help file and On-Line User's Guide. New QuickTours show how to get the most from the new features and program enhancements in the EEG Suite.

July 6, 1999
MagicMarker Home Page: Try out MagicMarker's remote monitoring capabilities right here at the Persyst Web site. We've uploaded the Temporal Seizure and Status Epilepticus sample files from the Persyst CD-ROM that show the MagicMarker Web feature in action. MagicMarker's wide variety of software-based Instrument Panels lets you choose the one that will best highlight the changes in EEG activity that you are looking for. Use OneTouchEEG to jump right to the underlying EEG traces.

June 29, 1999
New Software Download Area (with a brand-new version of the EEG Suite!) There are new installation instructions for upgraders, so we've tailored the download pages for those of you who are upgrading, and those who are using the 30-day free trial.
EEG Suite Subscription: Stay up-to-date with an EEG Suite software subscription! You are eligible for free software upgrades for one full year after purchase. An EEG Suite subscription will ensure that you will always have the latest EEG Suite features and enhancements.

June 18, 1999
Insights: Your FREE Persyst EEG Suite User's Group Quarterly Newsletter.
Don't forget to sign up for the EEG Suite User's Group Announcements on the same User's Group page! These e-mail messages will let you know of software upgrades available for download, and new applications notes on the Persyst Web.

March 8, 1999
Computerized voltage topographic mapping on subdural grids to analyze epileptic zones in children with extra-temporal lobe epilepsies.
Analysis of Intracranial Spikes. This application note also shows the use of the new Spike Clustering Wizard. These and other clinical/program application notes are available from the FAQ/Applications page.

December 9, 1998
Persyst MagicMarker: See how you will be able to monitor your long-term EEG patients from anywhere with MagicMarker!
|